Tube
in Tube UHT/HTST
Individual tubes are utilized to give a wide variety of heating and cooling
duties. The tubes are manufactured to our own specification and are profiled
to give turbulence at the low flow rates to enable scale up to production.
¥Minimum sample required.
¥Flow rates from 10 to 40 Ltr per hour (Higher available by request).
¥Highly accurate electromagnetic flowmeter as option.
¥Product system pressures to 10 bar.
¥Heating to 152 deg C at the flow rates stated.
¥Cooling to below 5 deg C at the flow rates stated.
¥Holding tubes of any time available and can be placed wherever needed.
¥Built in refrigerator or your chilled water supply.
¥Built in true CIP (Clean In Place), flow for CIP more than 500 Ltr per hour.
¥Each heating section is individually controlled to enable a wide setting of
product temperatures.
¥2 Electrically heated hot water recirculators.
¥Optional touch panel control fascia with flow path of system.
¥No steam required.
¥SIP (Sterilise In Place) an option for Aseptic sampling.
¥Aseptic sampling when used with the optional Clean Bench.
¥In line homogeniser can be added either upstream or downstream.
¥Level sensor in hopper for easy wash out after product and CIP.
¥Computer interface with real time temperature recording.
¥Static mixers optional for difficult products.
Mobile
The machine is completely mobile, can be moved from one location to another
very easily and can be positioned in a wet or dry area.
Control
Each section is individually controlled and the flow path of the system is shown
when the option of the touch panel is taken.
The product is heated by pressurised hot water recirculators which are PID controlled
for greater stability and accuracy. The cooling is in 1 or 2 stages dependant
on the final cooling temperature required.
Product Pump
As standard a progressive cavity pump is used.
Pump options are available depending on the products to be processed.
Service connections
Only mains water and a suitable drain required.
Compressed air at 6 bar for the divert valves.
Voltages available
200, 220 or 240 volt single phase, 50 or 60 Hz.
200 volt 3 phase, 50 or 60 Hz.
380 volt 3 phase, 50 or 60 Hz.
415 volt 3 phase, 50 or 60 Hz.
Amps
Depending on voltage, minimum 20 amps, maximum 45 amps